Vector VEC061 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Napájecí adaptéry a střídače Vector VEC061. Vector VEC061 Owner`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 16
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
VEC061
OWNER’S MANUAL
& WARRANTY INFORMATION
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING
SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT.
BEFORE USE, READ AND UNDERSTAND ALL CAUTIONS, WARNINGS,
INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S BATTERY
MANUFACTURER GUIDELINES. FAILURE TO DO SO COULD RESULT IN
INJURY AND/OR PROPERTY DAMAGE
.
4140 SW 28TH WAY, FT. LAUDERDALE, FL 33312
TEL 954-584-4446 • FAX 954-584-5556
www.vectormfg.com
350 WATT
POWER INVERTER
700 WATT
PEAK
NEW
SOFT START
TECHNOLOGY
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - POWER INVERTER

VEC061OWNER’S MANUAL & WARRANTY INFORMATIONTHIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDINGSAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS

Strany 2 - IMPORTANT CABLE INFORMATION

1010WARNING - Do not use the inverter near flammable materials or in any locations that may accumulate flammable fumes or gases.5. OPERATING TIPS5.1

Strany 3

11The inverter draws less than 0.3 ampere from the battery when it is notsupplying power to a load. In most instances, the inverter can be left connec

Strany 4 - INTRODUCTION

1212NOTE: It is normal for the alarm to sound while the unit is being connectedto, or disconnected from, the power source. This is not indicative of a

Strany 5 - TER WORKS

138. TROUBLESHOOTING GUIDE:TABLE 1 - INVERTER POWER SWITCH TURNED ONTROUBLE/ INDICATION POSSIBLE CAUSE SUGGESTED REMEDYNo AC output – DC input below

Strany 6 - 4. INSTALLATION

14149. FUSE REPLACEMENTIf external fuses blow, (or breakers trip), then there is a short or overloadin the DC wiring. Find and fix the problem before

Strany 7

1511. WARRANTY2/4 YEAR GOLD SEAL LIMITED WARRANTY PROGRAMThis limited warranty program is the only one that applies to this product,and it sets forth

Strany 8 - 4.3 CONNECTION TO LOAD

© 2004 VECTOR MANUFACTURING, Ltd.FT. LAUDERDALE, FL 33312 MADE IN CHINALIMITATIONS: This warranty does not cover accessories, bulbs, fuses andbatterie

Strany 9

22IMPORTANT SAFETY INSTRUCTIONS To ensure reliable service, your power inverter must be installed and usedproperly. Please read the installation and o

Strany 10 - 5. OPERATING TIPS

3CONTENTS1. INTRODUCTION ...42. CONTROLS, INDICATORS AND CONNECTORS ...4,53. HOW

Strany 11

441.INTRODUCTIONYour new Vector MAXX350SST inverter is one in a series of the most advanced DC to AC inverters available today. With proper care and a

Strany 12 - 7. COMMON PROBLEMS

5Outlets accommodate either two or three pin AC plugs. An On/Off Switchturns the inverter circuitry On and Off. The switch is used to force reset ofin

Strany 13 - 8. TROUBLESHOOTING GUIDE:

663.2 THE MAXX 350SST OUTPUT WAVEFORMThe AC output waveform of the MAXX350SST is known as “modified sinewave”. It is a waveform that has characterist

Strany 14 - 10. SPECIFICATIONS

7CAUTION: The MAXX 350SST must be connected only to batteries witha nominal output voltage of 12 volts. The unit will not operate from a 6 volt batter

Strany 15 - 11. WARRANTY

884. Check to be sure that all connections between battery clips andterminals are secure.Direct Hardwiring to Power Source:Use #10 AWG wire if the in

Strany 16 - FT. LAUDERDALE, FL 33312

9into the AC receptacle(s). The green LED indicator lights to indicate that theinverter is functioning. Make sure the combined load requirement of you