OWNER’S MANUAL & WARRANTY INFORMATIONTHIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY,OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUC
OVER VOLTAGE PROTECTION - The MAXX 750 SST will automatically shut downwhen the input voltage exceeds 15.5 volts DC.SHORT CIRCUIT PROTECTION - Reverse
8. TROUBLESHOOTING GUIDETABLE 1 - inverter power switch turned onTROUBLE/ INDICATION POSSIBLE CAUSE SUGGESTED REMEDYNo AC output – DC input below 10
10. SPECIFICATIONSOutput Connection . . . . . . Dual North American Standard ReceptaclesOutput Voltage . . . . . . . . . . . . . . . . Approx 110
If The Extended Warranty was activated, this repair or replacement periodextends to four years from the purchase date.If the unit is repaired, new or
© 2004 Vector Manufacturing, Ltd.FT. LAUDERDALE, FL 33312 Made in China
IMPORTANT SAFETY INSTRUCTIONS To ensure reliable service, your power inverter must be installed and used properly.Please read the installation and ope
CONTENTS1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42. Controls, indicators and connectors . . .
1. INTRODUCTIONYour new Vector MAXX 750 SST inverter is one in a series of the most advancedDC to AC inverters available. With proper care and appropr
FIGURE 2 - Shows location of the cooling fan and DC terminals3. HOW YOUR VECTOR INVERTER WORKSThe inverter converts low voltage DC (direct current) fr
The modified sine wave produced by the MAXX 750 SST inverter has an RMS(root mean square) voltage of 110 volts, which is the same as standard househol
CAUTION: Reverse polarity connection will result in a blown fuse and may causepermanent damage to the inverter.CONNECTING TO A POWER SOURCE USING PROV
4.3 CONNECTION TO LOADThe MAXX 750 SST is equipped with dual standard North American AC powerreceptacles. Plug the cord from the equipment you wish t
5. OPERATING TIPS5.1 RATED VERSUS ACTUAL CURRENT DRAW OF EQUIPMENTMost electrical tools, appliances and audio/video equipment have labels thatindicate